Powerex Enterprise Co., Ltd.

Manufacturer of Electric, Electrical Prudocts Supply & Power Conditioners.

Products

Stand By UPS

standby ups

  • Model No: NS-A601/A102/B152/B202/B302
  • Factory Location: Taiwan
  • Sample Request: No
  • Target Markets: Worldwide

Detail Information

Description :

100% made in Taiwan it allows switching to UPS supply automatically when external power supply is off or abnormal over high or low voltage. It contains two steps AVR. Voltage regulation plus UPS provide quasi sine wave output offered lightening surge protection, noise filtering and short circuit protection for PC and servo and other small capacity IT equipment.

Specification :

ModelNS-A601NS-A102B-152B-202B-302
Capacity VA/Watts600VA/360W1000VA/600W1500VA/900W2000VA/1200W3000VA/1800W
InputVoltage110/115/120VAC or 220/230/240VAC
Voltage Range83VAC~143VAC or 166VAC~286VAC
Frequency47Hz~53Hz or 57Hz~63Hz
OutputVoltage110/115/120VAC or 220/230/240VAC±10%
Frequency50Hz or 60Hz±1Hz
WaveformSimulated sine wave
Transfer Time<4ms
OutletsNEMA5-15R*2pcs or the other typeNEMA5-15R*6pcs or the other type
BatteryBattery Voltage12V DC24V DC48V DC
Battery TypeHigh Rating 12V/5AH12V/4AHHigh Rating
12V/5AH
High Rating
12V/9AH
Battery Quantity1 PCS2 PCS4 PCS
Back up Time
(Load with 1 PC)
15 mins40 mins60 mins90 mins120 mins
Recharging Time8 hours to 90% after fully discharged
FunctionLine Conditioning
Regulation(AVR)
When input voltage too high or too low, it’s with rising or decreasing voltage function automatically
LED Display1 LED: Normal (steady on)
Discharging (slow blinking)
Battery low (quick blinking)
Overload/Short/UPS 
Cut-off (LED off)
10LEDs: Normal (Green)
Discharging (Green)
AVR on (Orange)
UPS cut-off (Orange)
Overheat (Red)
Battery level (5LEDs)
AlarmBuzzer on for Back-up mode, Battery low
Mute SwitchNoYes (can be switched)
DC Start(Cold start)While mains black out, it can use internal batteries to turn on the UPS
Auto Restart UPSWhile mains recover, it can turn on automatically
Output Auto DelayNoYes (delay 5 seconds)
Overload/Short ProtectionCircuit Breaker(Line mode), Fuse and Electronic Circuit (back-up mode)
Lightning/Surge Protection350J/10000A
Communication PortDry Contact (it can be matched with RUPS-2000 software for windows 95/98/NT/2000/ME/XP/Vista)
UPS For ElevatorNoYes (with huge starting current ability, 5 seconds delayed to send output,
dry contact function.  All cable connection are using terminal block)
Safety
Conformance
 EN62040-1-1
EN62040-2
EnvironmentTemperature0℃~40℃
Humidity0%~95% (non-condensing)
Audible Noise 
PhysicalNet weight (KGS)6.511.517.618.5UPS:14
Battery Bank:14
Dimension:WxHxD (cm)9.4x17x279.4x17x3916x24x4116x24x41
(2 sets)
    

Powerex Enterprise Co., Ltd.

  • Taiwan