1. Character:
-Multiple Microprocessor design base
-Detachable control panel with LCD
-Unity input power factor and wide input range
-Robust design with output transformer
-True sine-wave double conversion on-line UPS
-DC start and automatic self-diagnostic function
-Capacity of battery unlimited and alarm silent
-RS232 communication port and built-in SNMP slot
-High efficiency design to save electricity
-Low heat dissipation in long term operation
-Designed to operate under harsh environment
-Enhanced protections against lighting surges, disturbances etc..
2. Description:
Advanced Power Protection for Enterprise Network.
| MODEL | PM-6006MS-LED | PM-6006MS-LCD | |
| CAPACITY | Capacity | 6KVA / 4200W | |
| INPUT | Nominal Voltage | 1P2W 220Vac | |
| Voltage Range | 176~276Vac +/- 3Vac | ||
| Frequency | 50Hz or 60Hz +/- 8% | ||
| Power Factor | >= 0.98 | ||
| OUTPUT | Voltage | 220Vac +/- 1% (230V or 240V re-settable via LCD panel) | |
| Frequency | 50Hz or 60Hz +/- 8% Synchronized (Line Mode) 50Hz or 60Hz +/-0.5% (Battery Mode) | ||
| Wave-form | True Sine wave | ||
| Distortion (Tower) | =<2% THD (Linear Load), =<6% THD (Non-Linear Load) | ||
| Distortion (Rack) | <4% THD (Linear Load), <7% THD (Non-Linear Load) | ||
| Crest Ratio | 3:1 | ||
| BATTERY | Type | Maintenance free sealed lead-acid battery | |
| Capacity | 12V / 7Ah * 20pcs | ||
| Charger (Option) | Built-In 4.2A Charger | ||
| Built-In Charger | 2A | ||
| Back-up (Full/Half load) | 8 min. | ||
| BYPASS | Automatic | Overload and UPS failure | |
| Transfer Time | 0 ms( AC to DC & Inverter to Bypass) | ||
| INDICATOR UPSERVER (LCD Series) | LCD | UPS status, I/P&O/P Voltage& Frequency, Load %,Battery Voltage, Temperature, Event Log | |
| LED | Normal (Green), Warning (Yellow), Fault (Red) | ||
| Display (LED Series) | LED | AC input (Green), Bypass (Yellow), Battery Low (Yellow), Inverter (Green), Load% (5 LEDs), Battery % (5 LEDs), Fault (Red) | |
| AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | |
| Battery Low | Beeping every seconds | ||
| Overload | Beeping twice per second | ||
| Fault | Beeping Continuously | ||
| INTERFACE | RS-232 Interface | UPSilon 2000 monitoring software | |
| SNMP | For Net Agent II (Option) with SNMP manager and Web browser | ||
| NETWORK | Surge Protection | RJ45 I/O port available for 10 base-T network or Fax / Modem | |
| ENVIRONMENT | Temperature | 0-40 degree C; 32-104 degree F | |
| Humidity | 20-90% non-condensing | ||
| Acoustic Noise | Less than 55dBA (at 1 meter) | ||
| NET WEIGHT | w/o battery | 90kgs | |
| w/ battery | 18.3kgs | ||
| Dimension (WxHxD) mm | Tower Case | 260 x 717 x 570 | |
| Rack Case (2U) | 482.6 x 132 x 600 | ||